-40%
MESR-100 V2 ESR/LOW Ohm In Circuit test Capacitor meter with SMD Clip Probe USA
$ 29.04
- Description
- Size Guide
Description
Store categorySign Up Now !
You may also like
MESR-100 V2 ESR/LOW Ohm In Circuit test Capacitor meter with SMD Clip Probe ship from USA
Product Description
Brand
JINGYAN
Model
MESR-100
Country of Manufacture
China
MPN
MESR-100 tester
Country/Region of Manufacture
China
MESR-100 V2 ESR/LOW Ohm In Circuit testing Capacitor meter include SMD Clip Probe
with LCD Display
Features:
JINGYAN MESR-100 V2 Auto-ranging capacitor ESR and Low Ohm Meter
Measuring range from 0.001 to 100.0R, support IN CIRCUIT Testing.
Using true 100 KHz sine wave to measure the ESR value, which is equal to the testing method of capacitor manufacturer.
In the market, there is some technique using short pulse method to testing, but the value will be varying vs the capacitance and sometimes reading is different from the manufacturer's value.
What is ESR of capacitor?
There is a series resistor inside capacitor, using 100kHz to remove the impedance 1/(2*pi*F*C), the impedance become small, and we can then measure the true series resistor value.
A bad E-capacitor will have larger ESR and create large ripple rather than filtering noise. Normally, a big capacitor is larger than 3 ohm.
Using this theory, we can measure the capacitor is bad/ damaged or good in condition.
Because our ESR meter only applies less than 15mV DC or peak to peak on a good capacitor, as a result we can use it as in circuit test. Because this low testing voltage, it cannot turn on the semiconductor inside a circuit under testing.
During repairing TV, LCD, Audio board, etc. we can in circuit testing the capacitor is good or not.
*Dual terminal, for fast and easy inspect general capacitor or resistor, a printed ESR table for fast check
Compare MESR100 old V1 and new V2 Improvement:
1)
Change square wave to sine wave 100 KHz, reduce square wave’s high frequency component, and affect the reading passing the test leads and capacitor.
2)
Higher Resolution up to 0.001 ohm.
3)
128X64 dot matrix LCD, with more larger value display and information
4)
Embedded 25V capacitor table at LCD, auto display the capacitor is good or bad reference to common 25V electrolytic capacitor.
5)
New plastic case, curve design for hand carrying. New stand for 60 degree stand on desk.
6)
Use 2X AA battery, more convenience and longer battery life than 9V battery.
7)
Support external USB power, using standard micro-USB port.
Specification:
Range
Accuracy (After Zero, tested with 1,10,100R resistor)
Refresh Time (Manual Mode)
*Auto mode take 0 to 2s more time depend on value
0.000 to 1.000R
1%+2Digit
~0.4s
1.000 to 10.00R
1%+1Digit
~0.4s
10.00 to 100.0R
2%+1Digit
~0.4s
*Accuracy maybe affected by the test lead’s length and contact point resistance.
Standard test leads is 15cm, for longer test leads need special shielding to affect the EMI inference (Can contact sales’ person for more detail)
1)
Accuracy: Up to 1% (detail on above table)
Wide Measurement Range: >1uF (for 0.1uF the error will be larger on equation 1/(2*pi*F*C) @ 100Khz )
2)
High Resolution: 4 digit, or 0.001Ohm @ 1 Ohm range
3)
Measuring voltage: <~40mV RMS (TESTING VOLTAGE)
4)
Clamping voltage: ~0.15V (open voltage)
5)
Battery 2X AA 1.5V battery
6)
External Power: 5V micro USB
7)
Operating current 0.02A
8)
Battery Life time: >80 Hours
Operating Introduction:
1)
POWER ON
Press and hold the ON/ OFF circle orange button for 2 to 3 second to power on.
Press and release the ON/ OFF button to shut down meter.
2) AUTO/ MANUAL mode:
i) Auto Range:
Press and release the RANGE button and at the first line of LCD will show “AUTO:"
At auto mode meter will automatically select the best range to detect.
ii) Manual Range:
Scroll the manual range from 1R, 10R and 100R range by press and release the RANGE button
In LCD will show MANUAL at first LCD line and show at second line: 0-1R, 1-10R and 10-100R.
3) 1 Key Zero:
Short circuit the test leads’ terminal, cancelling the wire resistance.
Press and release the “ZERO" button, LCD shows “ZERO" and wait the zero disappear.
If you are using the meter array socket, you need to use a short pin to short circuit to set zero.
4) Backlight:
LCD backlight will on during power on
5) Auto Sleep:
Around 10 hours for not testing, it will shut down automatically to save power.
6) OVERFLOW or OL:
Display overflow when the value is out of range, you can check that you are zero correctly.
7) ESR TABLE:
It is for reference only, different manufacturer of capacitor has different ESR, better to test a good cap ESR and compare with what you are testing, usually bad cap with higher ESR few times larger than good one.
8) SOFTWARE ESR:
Put the 25V Electrolytic capacitor value to LCD, and compare,
GOOD if C < XXuF, means the capacitor maybe good condition if it is less than XXuF
9) PLASTIC STAND:
If you don’t use the stand, press and push the lock position
Package include:
1 PCS MESR-100 V2 meter
(no including batteries in the package!!!)
1
pair
test probe
1 PCS SMD clip probe
Payment
Delivery details
feedback
About us
Contact us
Payment
We Only Accept Paypal on Ebay. For specific requirements, please feel free to contact us.
Delivery details
Ship from our
warehouse in USA
Estimated
delivery time: 2-5 business days
Please note: in special situation, there maybe the delay, please understand!
feedback
We appreciate every customer's feedback. We would be very grateful if you can give us some advice on our products.
If you have any complaints, you can contact us and we will actively find a suitable solution. No communication and leaving the neutral or negative feedback may unadvisable and cannot solve any problems.
We wish you a happy shopping here!
About us
We specialize in selling Programmer&Adapter products, as well as other Development&Repair&Test tools. We have been doing business in this field for many years
and have established good cooperative relations with customers from all over the world
. We can provide
professional
technical support about our products.
- we know user better!
Contact us
Any questions, please don't hesitate to contact us. Your messages are warmly welcomed. We will reply to you as soon as possible. Because of the time difference, there may be a little delay in response, please understand!
About return request:
Please don't be easy to open "return request".
Our company location is in Shanghai, China. We know international return is complex and long, so before strong packing and sending out, we test item well to avoid failures. If any problems, before opening "return request", please firstly send message to clearly explain your question in English. Maybe we can resolve your problem without "return item", this is the win-win situation.
We are looking forward to serving you!
Feedback