-40%
MESR-100 V2 AutoRanging In Circuit ESR Capacitor Tester Meter 0.001 to 100R New
$ 31.41
- Description
- Size Guide
Description
Store categorySign Up Now !
You may also like
New MESR-100 V2 AutoRanging In Circuit ESR Capacitor Tester Meter 0.001 to 100R
Product Description
MESR-100 V2 Auto-ranging capacitor ESR and Low Ohm Meter
Measuring range from 0.001 to 100.0R, support IN CIRCUIT Testing.
Using true 100 KHz sine wave to measure the ESR value, which is equal to the testing method of capacitor manufacturer.
Change square wave to sine wave 100 KHz, reduce square wave’s high frequency component, and affect the reading passing the test leads and capacitor.
Embedded 25V capacitor table at LCD, auto display the capacitor is good or bad reference to common 25V electrolytic capacitor.
What is ESR of capacitor?
There is a series resistor inside capacitor, using 100kHz to remove the impedance 1/(2*pi*F*C), the impedance become small, and we can then measure the true series resistor value.
A bad E-capacitor will have larger ESR and create large ripple rather than filtering noise. Normally, a big capacitor is larger than 3 ohm. Using this theory, we can measure the capacitor is bad/ damaged or good in condition. Because our ESR meter only applies less than 15mV DC or peak to peak on a good capacitor, as a result we can use it as in circuit test. Because this low testing voltage, it cannot turn on the semiconductor inside a circuit under testing. During repairing TV, LCD, Audio board, etc. we can in circuit testing the capacitor is good or not.
Note:
Accuracy maybe affected by the test lead’s length and contact point resistance. (Standard test leads is 15cm)
PLEASE DISCHARGE THE CAPACITOR BEFORE TESTING, you can use a screwdriver to short circuit, or series with a resistor around 10 ohm and short for 5 to 10s.
There is 2 fast diode inside the meter to prevent high voltage, but it is important to discharge the capacitor firstly, as it is a large surge current and voltage and may damage the meter.
Operating Introduction:
1
.POWER ON
Press and hold the ON/ OFF circle orange button for 2 to 3 second to power on.
Press and release the ON/ OFF button to shut down meter.
2.AUTO/ MANUAL Mode:
a) Auto Range:
Press and release the RANGE button and at the first line of LCD will show “AUTO:"
At auto mode meter will automatically select the best range to detect.
b
)
Manual Range:
Scroll the manual range from 1R, 10R and 100R range by press and release the RANGE button
In LCD will show MANUAL at first LCD line and show at second line: 0-1R, 1-10R and 10-100R.
(
3
)
1 Key Zero:
Short circuit the test leads’ terminal, cancelling the wire resistance.
Press and release the “ZERO" button, LCD shows “ZERO" and wait the zero disappear.
If you are using the meter array socket, you need to use a short pin to short circuit to set zero.
Backlight:
(4) LCD backlight will on during power on
(5) Auto Sleep:
Around 10 hours for not testing, it will shut down automatically to save power.
(6) OVERFLOW or OL:
Display overflow when the value is out of range, you can check that you are zero correctly.
(7) ESR TABLE:
It is for reference only, different manufacturer of capacitor has different ESR, better to test a good cap ESR and compare with what you are testing, usually bad cap with higher ESR few times larger than good one.
(8) SOFTWARE ESR:
Put the 25V Electrolytic capacitor value to LCD, and compare, GOOD if C < XXuF, means the capacitor maybe good condition if it is less than XXuF
(9) PLASTIC STAND:
If you don’t use the stand, press and push the lock position:
Specification:
Range
Accuracy (After Zero, tested with 1,10,100R resistor)
Refresh Time (Manual Mode)
*Auto mode take 0 to 2s more time depend on value
0.000 to 1.000R
1%+2Digit
~0.4s
1.000 to 10.00R
1%+1Digit
~0.4s
10.00 to 100.0R
2%+1Digit
~0.4s
Accuracy
Up to 1% (detail on above table) Wide Measurement Range: >1uF (for 0.1uF the error will be larger on equation 1/(2*pi*F*C) @ 100Khz )
High Resolution
4 digit, or 0.001Ohm @ 1 Ohm range
Measuring voltage
<~40mV RMS (TESTING VOLTAGE)
Clamping voltage
~0.15V (open voltage)
Battery
2X AA 1.5V battery
External Power
5V micro USB
Battery Life time
>80 Hours
Operating current
0.02A
Package Content:
1 X ESR Capacitor
1 X Pair Test Clips
Payment
Shipping time :
Feedback
Return Policy
Contact us
Payment
1.We accept PayPal payment only
2.Orders will be processed instantly and dispatched within 1-2 days, so we do NOT accept any email/message note after you place orders.
3.IMPORTANT! PLEASE READ! Buyers are responsible for import duties, custom fees and taxes, if any. Please check with your country's custom office to determine the additional costs impose on the item prior to buying.
Shipping time :
1.Items are shipped from china.we will send out within 1 bussiness day after receive the payment.
2.We only ship to ebay confirmed address. So before bidding, please kindly verify your ebay address.
3.Shipping to USA takes 8-18 days in normal condition by E-packet with tracking number.
Shipping to most other countries takes about 12-30 days via Economy Int'l Airmail.
Less than , without free tracking number,if you request tracking number,please send ebay message to us.
Over ,with tracking number free.The shipping time depends on your location and local postal service,as well as the weather condition along the shipping,sometimes may take longer,.please send ebay message to us if you didn't get your package.
4.Express shipping: Extra -- will be charged for the first 500 grams for most countries. Send ebay message to us if you need this service.
Feedback
If you are considering giving a neutral or negative or a low DSR(4 star or below), do write to us and give us an opportunity to address your concerns first. We are always stand-by to help for any questions or concerns.
Positive feedback is automatically left for you after you left to us positive feedback.
Return Policy
1. 12-months Warranty for defective items (excluding items damaged and/or misused after receipt).
Buy with confidence
2. Refund or replacement request is available only the requests within 2 week after parcel received & returning the item as the same condition as received.
3. Please contact us to request a return authorization. Your name, auction number, and reason for return should be included in the email. All items returned must contain all original packaging materials.
4. Please repack the item carefully. Items returned will be tested and a new replacement will be shipped to the buyer immediately when found defective. In the event that a suitable replacement is not available then a refund will be issued. Shipping, handling and insurance fees are non refundable.
5. Return shipping is to be paid by the Buyer.
Contact us
1.If you’re in any way dissatisfied or any question with your purchase,please feel free to contact us via ebay messages.And will response within 48 hours.We will try our best to solve it for you.We are committed to ensuring that you are completely satisfied with every transaction.
Your satisfactory is our goals
2.Please allow 1-2 business days for us to response. If you do not receive any reply from us,please check your email ensuring your mailbox has not reached full size.
3.Due to some ISP SPAM filter settings, you may not be able to receive our replies; if you have problems receiving our emails, you may need to use a different email account to contact us.
4.If you encounter any trouble. Please give us the opportunity to resolve any problem. We understand the concerns and frustrations you might have and will try our best to resolve the issues.
5.We care about our valued customers and will always try to help you. So if you have any problems, please contact us promptly.
Feedback