Product DescriptionFeatures:
It is applied with CMOS double-bevel A/D convertor that is automatic in zeroing and polar selection, and makes instruction for beyond measuring range.
Wide measuring range, covering 9 measuring sections from 0.1pF to 20,000μF that includes nominal value of any capacitance.
Biggest display value: 1999(3 1/2).
Reading: 2-3 readings/sec.
Zeroing: There is a zeroing knob on the front, easy for operation.
Data hold: Put the "HOLD" switch to "ON" and the DH sign will appear on the display.
Temperature for accurate measuring: 25±5°C
Temperature range: working temperature: 0 to 40°C
Storage temperature: -10 to 50°C
Relative humidity: <80%
Power supply: 9V laminated battery(Not included)
Specifications:
Accuracy: ±(%reading±digits) Quality guarantee: one year
Environment temperature: 25°±5°
Relative humidity: <80%
Rang Accuracy Definition Testing frequency
200pF ±0.5% ±20digit 0.1pF 800Hz
2nF ±0.5%±20digit 1pF 800Hz
20nF ±0.5%±20digit 10pF 800Hz
200nF ±0.5%±20digit 0.1μF 800Hz
2μF ±0.5%±20digit 1nF 800Hz
20μF ±0.5%±20digit 10nF 80Hz
200μF ±0.5%±20digit 0.1μF 8Hz
2000μF ±2.0%±20digit 1μF 8Hz
20000μF ±4.0%±20digit 10μF 8Hz
Color: Grey+Red
Dimension: about 148 x 75 x 33 mm
Weight: about 173 g
Package weight: about 193 g
Package included:
1 x Capacitance Tester
2 x Probes
Operation:
Firstly, check a 9V battery whether its electric voltage is short that will show signal on the left-upper of the LCD. Secondly, pay attention to the polarity or the capacitance to be tested. Thirdly, recharge the capacitance meter before measuring.
1. Select proper measuring section according to the capacitance to be tested.
2. Check and use the zeroing knob on the front of the meter to adjust the value to zero before measuring.
3. Insert the black sensor into the jack with "-" signal and the red sensor into the jack with "+".
4. Connect the capacitance to be tested with the two sensors. Pay attention to the polarity of the capacitance! Read capacitance numerical value displayed.
Notes:
a. If you don't know the approximate value of a capacitance, you should select measuring section of 200nF and then make relevant adjusting according to practical situation.
b. If the capacitance is in short circuit, the meter shows "beyond measuring range". If the capacitance is in electric leakage, the meter shows "beyond measuring range" or "much bigger than the normal value". If the capacitance is open-circuit, the meter shows "Zero" or "several pF".
c. In testing small capacitance, directly insert the capacitance into the jack instead of using the sensors for better accuracy.
Maintenance:
The meter is of highly accurate electronic apparatus. Don't change its internal circuit rashly for no damage to the meter.
1. Don't exert electric voltage upon the jack parts of the meter for no damage to the meter.
2. Don't test the sensors in short circuit , or the battery will be consumed out quickly.
3. Don't use a meter whose back cover doesn't cover the meter well.
4. Always replace battery and fuse after taking sensors out of a meter that is switched off. First, screw bolts in the back cover out. Second, take off the back cover. Third, replace battery and fuse according to specification provisioned in the operation manual. Suitable fuse for this meter is 200mA/250V, which external dimension is φ5×20㎜.
5. Please take out the battery when not using for a long time.
If you have any uncertainty or feel confused about the item, please feel free to contact us, your problem will be solved ASAP!
Payment
1.We accept PayPal only.
2.All major credit cards are accepted through secure payment processor PayPal.
3.Payment must be received within 7 business days of auction closing.
4.International buyers please note:
a.Import duties, taxes and charges are not included in the item price or shipping charges. These charges are buyer’s responsibility. We will try our best to reduce the risk of the custom duties.
b.Please check with your country's customs office to determine what these additional costs will be prior to buying.
Shipping
1.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
2.Items will be shipped within 2 business day when we received payment.
3.Delivery time depends on destination and other factors;
4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
Returns
1. To Return an item you must contact us and take photos of your item to clearly show any damage or unusual aspects of it.
2. Approved returns will be subject to inspection on arrival. Items must be returned in original condition with all original packaging.
3. All shipping and handing charges are non-refundable.
4. Return delivery costs are the responsibility of the buyer. We will cover the cost if sending replacement/repaired items.
5. Within 7 days after receiving your products, we offers a no-hassle 7 day exchange/replace only if your items are found to be defective by manufacturer.
powered by